To reduce the risk of exogenous bacterial infections, establishing infection control is critical to dermatologist practice. The most important aspects of infection control are sterility and disinfection. Both disinfection and sterilization are procedures for the safe disposal and sterilization of medical instruments in the operating room.

  • Product Description
  • Technical Parameters
  • Video

Steam Sterilization Surgical Instruments Operating Room Sterilization Equipment Description:

The most common instrumental sterilization method for operating room instruments is steam or autoclave. Surgical instruments in particular should be disinfected regularly. sterilization surgical instruments Sterilization surgical instruments are usually performed using an autoclave. This is the least invasive, fastest, and most effective way to achieve sterility.

Steam sterilization is a popular and effective sterilization method for a variety of medical devices, including catheters and implants. Because steam is so powerful, you can use it to kill bacteria.

sterilization surgical instruments,steam sterilization,autoclave steam sterilizer,sterilization equipment

Steam Sterilization Surgical Instruments Features:

1. The sterilization cabinet inner shell is made of high quality stainless steel, beautiful and corrosion resistant;

2. the sealing door adopts pneumatic sealing structure, safe and reliable, easy to operate.

3. pulsating mode forced to exclude sterilization of cold air in the room, articles sterilization thoroughly, high efficiency, good drying effect;

4. the pipeline system adopts imported stainless steel Angle seat valve and stainless steel internal polishing pipe fitting, pipe louie cleaning, no dead Angle;

5. Processing and manufacturing in accordance with GMP standards, with a perfect document system;

6. microcomputer control automatic operation, recording, printing;

7. Imported configuration, reliable system operation;

8. Stainless steel inner car and outer cover.

 

Sterilization process:

Pulsating vacuum →Heating → sterilization → Exhaust → Drying → End

sterilization surgical instruments,steam sterilization,autoclave steam sterilizer,sterilization equipment

Leave a Reply

Your email address will not be published. Required fields are marked *

Design pressure0.245MpaVacunm-0.095Mpa
Working Pressure0.22MpaSteam Source Pressure0.4-0.6Mpa
Design Temperature139℃Water Source Pressure0.1-0.3Mpa
Working Temperature134℃Compressed Air Pressure0.5-0.7Mpa
SpecificationsOverall DimensionsChamber SizeSteam ConsumptionPowerWater ConsmptionNet Weight
ModelL*M*H(mm)L*W*H(mm)(kg/cycle)(KW)(kg/cycle)(kg)
Single/Double Door
YG-0.1825*1080*1600630*400*48015180380
YG-0.25895*1220*1720760*600*600201.5150650
YG-0.361195*1220*17201000*600*600251.5150760
YG-0.61245*1300*18801050*680*8503022001100
YG-0.81595*1300*18801400*680*8503532501300
YG-1.21695*1370*19601500*750*11004033001900
YG-2.53195*1370*19603000*750*1100754.54502800
YG-5.03635*1800*22003400*1000*15001507.56004500