Zhangjiagang City, Jiangsu Province, China.
+86-512-58810663
To reduce the risk of exogenous bacterial infections, establishing infection control is critical to dermatologist practice. The most important aspects of infection control are sterility and disinfection. Both disinfection and sterilization are procedures for the safe disposal and sterilization of medical instruments in the operating room.
The most common instrumental sterilization method for operating room instruments is steam or autoclave. Surgical instruments in particular should be disinfected regularly. sterilization surgical instruments Sterilization surgical instruments are usually performed using an autoclave. This is the least invasive, fastest, and most effective way to achieve sterility.
Steam sterilization is a popular and effective sterilization method for a variety of medical devices, including catheters and implants. Because steam is so powerful, you can use it to kill bacteria.

1. The sterilization cabinet inner shell is made of high quality stainless steel, beautiful and corrosion resistant;
2. the sealing door adopts pneumatic sealing structure, safe and reliable, easy to operate.
3. pulsating mode forced to exclude sterilization of cold air in the room, articles sterilization thoroughly, high efficiency, good drying effect;
4. the pipeline system adopts imported stainless steel Angle seat valve and stainless steel internal polishing pipe fitting, pipe louie cleaning, no dead Angle;
5. Processing and manufacturing in accordance with GMP standards, with a perfect document system;
6. microcomputer control automatic operation, recording, printing;
7. Imported configuration, reliable system operation;
8. Stainless steel inner car and outer cover.
Pulsating vacuum →Heating → sterilization → Exhaust → Drying → End

| Design pressure | 0.245Mpa | Vacunm | -0.095Mpa |
| Working Pressure | 0.22Mpa | Steam Source Pressure | 0.4-0.6Mpa |
| Design Temperature | 139℃ | Water Source Pressure | 0.1-0.3Mpa |
| Working Temperature | 134℃ | Compressed Air Pressure | 0.5-0.7Mpa |
| Specifications | Overall Dimensions | Chamber Size | Steam Consumption | Power | Water Consmption | Net Weight |
| Model | L*M*H(mm) | L*W*H(mm) | (kg/cycle) | (KW) | (kg/cycle) | (kg) |
| Single/Double Door | ||||||
| YG-0.1 | 825*1080*1600 | 630*400*480 | 15 | 1 | 80 | 380 |
| YG-0.25 | 895*1220*1720 | 760*600*600 | 20 | 1.5 | 150 | 650 |
| YG-0.36 | 1195*1220*1720 | 1000*600*600 | 25 | 1.5 | 150 | 760 |
| YG-0.6 | 1245*1300*1880 | 1050*680*850 | 30 | 2 | 200 | 1100 |
| YG-0.8 | 1595*1300*1880 | 1400*680*850 | 35 | 3 | 250 | 1300 |
| YG-1.2 | 1695*1370*1960 | 1500*750*1100 | 40 | 3 | 300 | 1900 |
| YG-2.5 | 3195*1370*1960 | 3000*750*1100 | 75 | 4.5 | 450 | 2800 |
| YG-5.0 | 3635*1800*2200 | 3400*1000*1500 | 150 | 7.5 | 600 | 4500 |